


Polyurethane 66x66x109 cm Pilaster Column
Technical Specifications
| Material | Polyurethane decorative material |
|---|---|
| Surface | Decorative surface |
| Color | Paintable production surface |
| Density | 150-220 kg/m³ |
| Water Absorption | below 1% |
| Dimensional Stability Test | -20 °C / +70 °C |
| Fire Class | B2 (DIN 4102-1) |
| Paintable | Yes |
| Usage | Indoor + Outdoor |
| Water Resistant | Yes |
| Diameter | Ø 66 cm |
| Dimensions | 657 × 657 × 1090 mm |
| Sales Unit | piece |
Details
Support
Similar Products(Architectural Pilaster Columns)
















































The Polyurethane Pilaster Column is a decorative architectural element designed to give walls, entrances and existing structural columns a more defined vertical composition. Measuring 66 × 66 × 109 cm, P5060B creates a substantial pilaster presence suited to projects that require a clear classical reference without adding the weight associated with stone, concrete or solid timber components. It is decorative only and is not intended to carry structural loads.
P5060B is cast from rigid, closed-cell polyurethane with a density of 150-220 kg/m³. The closed-cell structure has water absorption below 1%, helping the profile remain suitable for humid locations and exterior applications when finished correctly. Dimensional stability has been tested at -20 °C / +70 °C; this refers to dimensional-stability testing rather than a service-temperature rating. The material is considerably lighter than plaster, concrete and solid wood, while retaining a firm surface that can reproduce crisp decorative geometry.
The 66 × 66 cm footprint gives this pilaster column a broad, architectural scale, while the 109 cm height makes it appropriate as a distinct vertical section within a layered wall or column composition. Its decorative factory-finished surface is supplied with a primer layer that prepares it for painting. No motif or ornament should be assumed beyond the supplied product finish, allowing the chosen paint colour and surrounding mouldings to determine the final visual character.
Polyurethane Pilaster Column P5060B can be used in entrance halls, living rooms, hotel reception areas, restaurants, offices and retail interiors to frame wall fields or dress existing columns. On facades, it can support the visual rhythm of villa entrances, door surrounds and covered terrace walls. For exterior installation, a UV-resistant paint system is required. The product can be painted in a matching façade colour or used in a contrasting tone to articulate pilaster lines around an entrance.
Installation starts with a clean, dry and level substrate. Check the 66 × 66 × 109 cm dimensions before fitting, prepare any 45° mitre joints where the design requires them, and bond the element with polyurethane (PU) mounting adhesive. Mechanical fixing with screws is mandatory; suitable anchors may also be required according to the substrate and project conditions. Fill joints and screw points, sand with 180-220 grit abrasive, then apply primer and two paint coats. Compared with plaster, P5060B is lighter and less prone to breakage; compared with timber, it is not vulnerable to rot or insect damage.
The factory primer supports paint adhesion, but an additional primer remains optional and should be selected according to the paint manufacturer’s instructions. Paint manufacturers may not guarantee coatings applied without their own recommended primer system. Polure does not guarantee paint products or accept responsibility for the selected coating system. Product pricing depends on the selected specification and project requirements.
- P5060B is suited to interior and exterior schemes where a wall needs the visual order of a classical pilaster without constructing a masonry column
- In a living room or entrance hall, position the 66 × 66 cm element at the edges of a feature wall, fireplace composition or doorway to create a framed wall bay
- In hotel lobbies, restaurants and retail interiors, repeated pilaster positions can define seating zones, reception walls or long circulation routes
- For villa facades, covered entrances and terrace walls, the 109 cm height works well as a visible lower or intermediate architectural section within a larger column arrangement
- It can also be installed over an existing structural column where the decorative finish is required; P5060B itself does not provide load-bearing support
- Use a UV-resistant exterior paint on outdoor applications and seal joints and screw points with exterior-grade filler
- Matching the pilaster colour to window surrounds creates a coordinated facade composition, while a contrasting shade makes the vertical lines more pronounced
- Prepare a clean, dry, sound and level mounting surface before installing P5060B
- Confirm the product dimensions and planned alignment before adhesive application, especially when several pilaster elements are used in one wall composition
- Where corner or return details are required, cut the relevant edges at 45°
- Apply polyurethane (PU) mounting adhesive to the contact areas and position the decorative element accurately
- Mechanical fixing with screws is mandatory; select suitable anchors where the substrate or project detail requires additional support
- The product is decorative and must not be used as a structural member
- Fill joints and screw heads with compatible filler, sand the cured surface using 180-220 grit abrasive, then apply primer and two coats of paint
- For exterior work, close all joints and fixing points with exterior-grade filler and use a UV-resistant paint system
- Clean the painted surface with a soft dry cloth or a lightly damp cloth
- Avoid abrasive pads, aggressive solvents and harsh cleaners that may damage the paint film or decorative surface
- Inspect exterior installations periodically, particularly at joints, screw points and exposed edges, and renew sealant or paint where weathering is visible
- The factory primer prepares the surface for coating, but the final maintenance interval depends on the selected paint system, colour, exposure conditions and quality of installation
- Follow the paint manufacturer’s cleaning and repainting guidance
Can P5060B be used on an exterior facade?
Yes. P5060B is suitable for exterior decorative applications such as villa entrances, covered terraces, facade wall fields and existing structural columns. Its closed-cell polyurethane structure has water absorption below 1%, but this does not remove the need for a proper exterior coating system. Use UV-resistant exterior paint, seal joints and screw points with exterior-grade filler, and install the element on a clean, stable substrate. The product is decorative and does not function as a load-bearing column.
How is the P5060B Pilaster Column installed and painted?
Install P5060B on a clean, dry and level surface using polyurethane (PU) mounting adhesive together with mandatory mechanical screw fixing. Use appropriate anchors when required by the wall substrate or project detail. Check dimensions before fitting and make 45° mitre cuts where the layout needs corner connections. After installation, fill joints and screw heads, sand with 180-220 grit abrasive, apply primer and finish with two paint coats. For exterior installations, choose a UV-resistant paint.
How durable is a rigid polyurethane pilaster column?
P5060B is produced from rigid closed-cell polyurethane with a density of 150-220 kg/m³. It is much lighter than plaster, concrete or solid timber, yet provides a firm decorative surface for architectural applications. Water absorption is below 1%, and dimensional stability has been tested at -20 °C / +70 °C. Actual service life depends on correct installation, suitable paint selection, exposure conditions and periodic maintenance of exterior coating joints.
What advantages does polyurethane offer over plaster or wood?
A polyurethane pilaster column is easier to handle than comparable plaster, stone or concrete elements because of its lower weight. Unlike plaster, it is less vulnerable to breakage during handling and installation. Unlike solid timber, it is not susceptible to rot or insect damage. The cast manufacturing process also supports sharply defined decorative forms. P5060B still requires proper mechanical fixing, joint finishing and a suitable paint system to achieve a durable final result.
Is P5060B supplied ready for painting?
P5060B has a factory primer layer that prepares its decorative surface for painting. Water-based and synthetic paint systems can be used when selected according to the paint manufacturer’s technical guidance. An additional primer is optional rather than automatically unnecessary: paint manufacturers may not provide a coating guarantee unless their recommended primer is used. For exterior use, a UV-resistant paint is required because unpainted polyurethane may yellow under UV exposure.