













Polyurethane Pilaster Column Base, 28 x 55 x 94 cm
Technical Specifications
| Material | Polyurethane |
|---|---|
| Surface | Dekoratif poliüretan yüzey |
| Color | White |
| Density | Belirtilmemiş |
| Water Absorption | below 1% |
| Service Temperature | -100 °C / +80 °C |
| Fire Class | B2 (flame retardant) |
| Paintable | Yes |
| Usage | Indoor + Outdoor |
| Water Resistant | Yes |
| Diameter | Ø 28 cm |
| Dimensions | 277 × 554 × 940 mm |
| Sales Unit | piece |
Details
Support
Similar Products(Architectural Pilaster Columns)












































P5050B50 is a decorative pilaster column base designed to complete the lower section of a pilaster composition with a defined architectural termination. Measuring 28 x 55 x 94 cm in width, depth and height, the element gives a substantial visual base to vertical pilaster arrangements without the mass of masonry. Its white finish provides a neutral starting point for coordinated architectural colour schemes.
The P5050B50 pilaster base is produced from rigid, closed-cell polyurethane with a density of 150-220 kg/m³. This structure combines low weight with a firm surface suitable for decorative architectural work. Water absorption is below 1%, while the stated service temperature range is -100 °C / +80 °C. The material is resistant to moisture-related decay and retains dimensional stability under normal application conditions. It is difficult to ignite and self-extinguishes when the flame source is removed.
As a lower pilaster element, the 94 cm height creates a clearly proportioned transition between the floor or plinth zone and the vertical shaft above it. The 28 x 55 cm footprint is suitable for projects where the base must read clearly from the front and side. The supplied information does not define a separate ornamental motif, so the product can be integrated into both restrained and more detailed pilaster compositions through colour, surrounding profiles and the selected shaft design.
P5050B50 can be used in entrance halls, living rooms, stair landings, hotel lobbies, restaurant interiors, office reception areas and villa foyers. Outdoors, it can form the lower section of a decorative pilaster on a facade, entrance surround or covered terrace elevation. It is a decorative component rather than a structural support and must not be used to carry building loads. When installed outside, protect the finished surface with UV-resistant paint.
For installation, prepare a clean, dry and even substrate, check the alignment of the complete pilaster layout, and make accurate 45-degree mitre cuts where required. Apply polyurethane (PU) mounting adhesive and secure the element with mechanical fixing using suitable screws and anchors; silicone is not an appropriate adhesive for this application. Fill joints and fixing points, sand with 180-220 grit abrasive, apply any additional primer required by the chosen paint system, and finish with two coats. The factory primer prepares the surface for water-based or synthetic paint, but additional primer remains optional because paint manufacturers may not provide a warranty without their own primer. Polure does not warrant third-party paint systems.
Compared with plaster, the P5050B50 base is easier to handle and less prone to breakage during fitting. Compared with timber, it offers greater resistance to moisture, decay and insects, while its rigid surface accepts filling, sanding and repainting. These characteristics make the pilaster base suitable for renovation work as well as new decorative schemes.
- P5050B50 is intended for the lower section of pilaster column compositions
- In a living room, it can frame a fireplace wall, media wall or wide opening when paired with a matching vertical shaft
- In an entrance hall or stair landing, the 94 cm height gives the pilaster a strong visual start without requiring a heavy masonry base
- Hotel lobbies, restaurant entrances and office reception areas can use it to define portals, wall bays or decorative columns
- For villa facades, the base can be placed beneath pilasters at entrance portals, around major openings or on covered terrace elevations
- The 28 x 55 cm footprint should be checked against the shaft and the available wall depth before ordering
- Outdoors, use a UV-resistant paint system and seal joints and fixing points with exterior-grade filler
- Because the element is decorative and not structural, it should be installed over or beside the building's actual load-bearing construction rather than used as a support
- Coordinate the white factory finish with the surrounding cornices, capitals, shafts and facade colour for a continuous architectural composition
- Begin by checking the substrate and the complete pilaster layout
- The surface must be clean, dry, sound and sufficiently even for full contact
- Position the P5050B50 base and mark the final alignment before applying adhesive
- Where mitred joints are required, use accurate 45-degree cuts and dry-fit the pieces first
- Apply polyurethane (PU) mounting adhesive to the prepared contact areas; do not use silicone
- Mechanical fastening with suitable screws and anchors is mandatory, with the fixing method selected according to the substrate and project conditions
- Wider or exposed applications may require additional mechanical support
- Fill seams and screw recesses with suitable filler, allow the surface system to set according to its product instructions, then sand with 180-220 grit abrasive
- Apply an additional primer only if required or preferred by the selected paint manufacturer, followed by two coats of water-based or synthetic paint
- Exterior applications require UV-resistant paint and sealed joints
- Clean the P5050B50 surface with a soft, slightly damp cloth and avoid abrasive pads, aggressive solvents or tools that may mark the finish
- For painted installations, follow the maintenance instructions of the selected paint manufacturer
- Inspect exterior joints, screw points and exposed edges periodically, particularly after severe weather
- If cracking, impact damage or coating failure appears, remove loose material, refill the affected area, sand it smooth and repaint
- Outdoor finishes should retain UV resistance; repainting intervals depend on the paint system, exposure and local conditions
- Do not attach loads to the decorative base or treat it as structural construction
Can the P5050B50 pilaster column base be used outdoors?
Yes. P5050B50 is suitable for interior and exterior decorative applications. On a facade, entrance surround or covered terrace, use a UV-resistant exterior paint and seal all joints and screw recesses with suitable exterior filler. The base is decorative and does not carry structural loads, so it must be fixed to the building construction with the correct adhesive and mandatory mechanical fastening. Weather exposure, substrate condition and the selected coating system affect long-term appearance.
How is the pilaster base installed and painted?
Prepare a clean, dry and even surface, position the base, and check alignment before bonding. Use polyurethane (PU) mounting adhesive and suitable screws and anchors for mechanical fixing; silicone should not be used. Mitre cuts, where needed, should be made at 45 degrees. Fill joints and fixing points, sand with 180-220 grit abrasive, and apply two coats of water-based or synthetic paint. The factory primer prepares the surface, while an additional primer is optional according to the paint manufacturer's system.
How heavy is it, and how long will the pilaster base last?
The product information does not specify an individual unit weight, so a weight should not be estimated from the dimensions alone. The rigid closed-cell structure has a density of 150-220 kg/m³ and is designed for durable decorative use when correctly installed and coated. Its water absorption is below 1%, and it resists decay and moisture-related deterioration. Actual service life depends on substrate preparation, fixing, paint quality, exposure and routine maintenance.
What advantages does it offer over plaster or timber?
The P5050B50 pilaster base is easier to handle than a comparable plaster or masonry element and is less susceptible to breakage during installation. Compared with timber, its closed-cell structure offers better resistance to moisture, decay and insect-related deterioration. The rigid surface can be filled, sanded and repainted, which supports repair and colour changes. It remains a decorative element, however, and should not be substituted for a structural column or load-bearing support.
Can the white surface be changed to another colour?
Yes. The white factory-primed surface is prepared for water-based or synthetic paint, allowing the pilaster base to match the wall, shaft, capital, facade or surrounding trim. Sand filled areas before coating and follow the chosen paint manufacturer's preparation and application instructions. An additional primer is optional, but some paint manufacturers may not warranty surfaces painted without their own primer. For exterior work, a UV-resistant paint is required to reduce yellowing and coating degradation.
Similar Products(Architectural Pilaster Columns)












































P5050B50 is a decorative pilaster column base designed to complete the lower section of a pilaster composition with a defined architectural termination. Measuring 28 x 55 x 94 cm in width, depth and height, the element gives a substantial visual base to vertical pilaster arrangements without the mass of masonry. Its white finish provides a neutral starting point for coordinated architectural colour schemes.
The P5050B50 pilaster base is produced from rigid, closed-cell polyurethane with a density of 150-220 kg/m³. This structure combines low weight with a firm surface suitable for decorative architectural work. Water absorption is below 1%, while the stated service temperature range is -100 °C / +80 °C. The material is resistant to moisture-related decay and retains dimensional stability under normal application conditions. It is difficult to ignite and self-extinguishes when the flame source is removed.
As a lower pilaster element, the 94 cm height creates a clearly proportioned transition between the floor or plinth zone and the vertical shaft above it. The 28 x 55 cm footprint is suitable for projects where the base must read clearly from the front and side. The supplied information does not define a separate ornamental motif, so the product can be integrated into both restrained and more detailed pilaster compositions through colour, surrounding profiles and the selected shaft design.
P5050B50 can be used in entrance halls, living rooms, stair landings, hotel lobbies, restaurant interiors, office reception areas and villa foyers. Outdoors, it can form the lower section of a decorative pilaster on a facade, entrance surround or covered terrace elevation. It is a decorative component rather than a structural support and must not be used to carry building loads. When installed outside, protect the finished surface with UV-resistant paint.
For installation, prepare a clean, dry and even substrate, check the alignment of the complete pilaster layout, and make accurate 45-degree mitre cuts where required. Apply polyurethane (PU) mounting adhesive and secure the element with mechanical fixing using suitable screws and anchors; silicone is not an appropriate adhesive for this application. Fill joints and fixing points, sand with 180-220 grit abrasive, apply any additional primer required by the chosen paint system, and finish with two coats. The factory primer prepares the surface for water-based or synthetic paint, but additional primer remains optional because paint manufacturers may not provide a warranty without their own primer. Polure does not warrant third-party paint systems.
Compared with plaster, the P5050B50 base is easier to handle and less prone to breakage during fitting. Compared with timber, it offers greater resistance to moisture, decay and insects, while its rigid surface accepts filling, sanding and repainting. These characteristics make the pilaster base suitable for renovation work as well as new decorative schemes.
- P5050B50 is intended for the lower section of pilaster column compositions
- In a living room, it can frame a fireplace wall, media wall or wide opening when paired with a matching vertical shaft
- In an entrance hall or stair landing, the 94 cm height gives the pilaster a strong visual start without requiring a heavy masonry base
- Hotel lobbies, restaurant entrances and office reception areas can use it to define portals, wall bays or decorative columns
- For villa facades, the base can be placed beneath pilasters at entrance portals, around major openings or on covered terrace elevations
- The 28 x 55 cm footprint should be checked against the shaft and the available wall depth before ordering
- Outdoors, use a UV-resistant paint system and seal joints and fixing points with exterior-grade filler
- Because the element is decorative and not structural, it should be installed over or beside the building's actual load-bearing construction rather than used as a support
- Coordinate the white factory finish with the surrounding cornices, capitals, shafts and facade colour for a continuous architectural composition
- Begin by checking the substrate and the complete pilaster layout
- The surface must be clean, dry, sound and sufficiently even for full contact
- Position the P5050B50 base and mark the final alignment before applying adhesive
- Where mitred joints are required, use accurate 45-degree cuts and dry-fit the pieces first
- Apply polyurethane (PU) mounting adhesive to the prepared contact areas; do not use silicone
- Mechanical fastening with suitable screws and anchors is mandatory, with the fixing method selected according to the substrate and project conditions
- Wider or exposed applications may require additional mechanical support
- Fill seams and screw recesses with suitable filler, allow the surface system to set according to its product instructions, then sand with 180-220 grit abrasive
- Apply an additional primer only if required or preferred by the selected paint manufacturer, followed by two coats of water-based or synthetic paint
- Exterior applications require UV-resistant paint and sealed joints
- Clean the P5050B50 surface with a soft, slightly damp cloth and avoid abrasive pads, aggressive solvents or tools that may mark the finish
- For painted installations, follow the maintenance instructions of the selected paint manufacturer
- Inspect exterior joints, screw points and exposed edges periodically, particularly after severe weather
- If cracking, impact damage or coating failure appears, remove loose material, refill the affected area, sand it smooth and repaint
- Outdoor finishes should retain UV resistance; repainting intervals depend on the paint system, exposure and local conditions
- Do not attach loads to the decorative base or treat it as structural construction
Can the P5050B50 pilaster column base be used outdoors?
Yes. P5050B50 is suitable for interior and exterior decorative applications. On a facade, entrance surround or covered terrace, use a UV-resistant exterior paint and seal all joints and screw recesses with suitable exterior filler. The base is decorative and does not carry structural loads, so it must be fixed to the building construction with the correct adhesive and mandatory mechanical fastening. Weather exposure, substrate condition and the selected coating system affect long-term appearance.
How is the pilaster base installed and painted?
Prepare a clean, dry and even surface, position the base, and check alignment before bonding. Use polyurethane (PU) mounting adhesive and suitable screws and anchors for mechanical fixing; silicone should not be used. Mitre cuts, where needed, should be made at 45 degrees. Fill joints and fixing points, sand with 180-220 grit abrasive, and apply two coats of water-based or synthetic paint. The factory primer prepares the surface, while an additional primer is optional according to the paint manufacturer's system.
How heavy is it, and how long will the pilaster base last?
The product information does not specify an individual unit weight, so a weight should not be estimated from the dimensions alone. The rigid closed-cell structure has a density of 150-220 kg/m³ and is designed for durable decorative use when correctly installed and coated. Its water absorption is below 1%, and it resists decay and moisture-related deterioration. Actual service life depends on substrate preparation, fixing, paint quality, exposure and routine maintenance.
What advantages does it offer over plaster or timber?
The P5050B50 pilaster base is easier to handle than a comparable plaster or masonry element and is less susceptible to breakage during installation. Compared with timber, its closed-cell structure offers better resistance to moisture, decay and insect-related deterioration. The rigid surface can be filled, sanded and repainted, which supports repair and colour changes. It remains a decorative element, however, and should not be substituted for a structural column or load-bearing support.
Can the white surface be changed to another colour?
Yes. The white factory-primed surface is prepared for water-based or synthetic paint, allowing the pilaster base to match the wall, shaft, capital, facade or surrounding trim. Sand filled areas before coating and follow the chosen paint manufacturer's preparation and application instructions. An additional primer is optional, but some paint manufacturers may not warranty surfaces painted without their own primer. For exterior work, a UV-resistant paint is required to reduce yellowing and coating degradation.