Polyurethane Decorative Material Pilaster Column 56x56x26 cm
Technical Specifications
| Material | Polyurethane decorative material |
|---|---|
| Surface | Decorative molded surface; can be painted after appropriate preparation. |
| Color | Paintable surface; final color depends on the selected paint system. |
| Density | Belirtilmemiştir. |
| Water Absorption | below 1% |
| Dimensional Stability Test | -20 °C / +70 °C |
| Fire Class | B2 (DIN 4102-1) |
| Paintable | Yes |
| Usage | Indoor + Outdoor |
| Water Resistant | Yes |
| Diameter | Ø 56 cm |
| Dimensions | 555 × 555 × 255 mm |
| Sales Unit | piece |
Details
Support
Similar Products(Architectural Pilaster Columns)
















































P5040D is a polyurethane decorative material pilaster column element designed to finish vertical architectural compositions with a defined, dimensional profile. Used around columns, entrances and interior wall features, this pilaster component creates a structured transition between the wall and the surrounding decorative design. Its 56 x 56 x 26 cm dimensions provide a substantial architectural presence while remaining suitable for carefully scaled residential, hospitality and commercial projects.
The element is manufactured from rigid, closed-cell polyurethane with a density of 150-220 kg/m³. This construction combines low weight with a hard, detailed surface that is easier to handle than plaster, stone or solid timber. Water absorption is below 1%, supporting use in humid locations when the complete paint and installation system is suitable. The material maintains dimensional stability, and this has been tested within -20 °C / +70 °C. It has fire class B2 (DIN 4102-1).
P5040D has a decorative molded surface that gives the pilaster head a clear architectural outline without requiring heavy masonry work. The visible relief and profile should be coordinated with the adjoining pilaster shaft, wall finish and surrounding trim. The surface is supplied with a factory primer that prepares it for a water-based or synthetic paint system. Additional primer application is optional, but paint manufacturers may not provide warranty coverage when their own primer is not used. Polure does not guarantee compatibility with selected paint products and accepts no responsibility for the chosen coating system.
P5040D can be specified for pilaster compositions in entrance halls, living rooms, dining areas, hotel lobbies, restaurants and office reception spaces. Outdoors, the element can be used on protected or exposed facade details after suitable preparation and painting with a UV-resistant exterior coating. It is also appropriate for framing a doorway, strengthening the visual termination of a pilaster, or giving a villa facade a more articulated vertical rhythm. The element is decorative only and must not be treated as a structural or load-bearing component.
For installation, prepare a clean, dry and sound substrate, then check the alignment before fixing. Use polyurethane (PU) mounting adhesive; silicone adhesive must not be used. Mechanical fixing with suitable screws and anchors is mandatory, with the fixing method selected according to the substrate, project conditions and product instructions. Fill joints and fixing points, sand with 180-220 grit abrasive paper, apply the selected primer if required by the paint system, and finish with two coats of compatible paint. Compared with plaster, the closed-cell polyurethane element is lighter and less prone to breakage; compared with timber, it resists moisture-related decay and insect damage while retaining a repairable, paintable surface.
- P5040D is intended for pilaster and column compositions rather than standalone structural work
- In a living room, it can frame a wall-mounted fireplace surround, doorway or built-in display area
- In an entrance hall, pair the element with a pilaster shaft to create a formal vertical arrangement around the main door or an opening between rooms
- Hotel lobbies, restaurant entrances and office reception areas can use it to give columns a more finished architectural termination
- For a bedroom, it can define the sides of a feature wall or create a framed backdrop behind the bed without adding the weight of stone or plaster
- On villa and commercial facades, the piece can complete pilasters around entrance doors, windows or selected vertical bays
- Exterior use requires a compatible UV-resistant paint system and careful sealing of joints and fixing points
- The 56 x 56 cm footprint gives the element a broad visual scale, while the 26 cm height makes it suitable for a concentrated capital or upper transition detail
- Coordinate its proportions with the adjoining shaft and surrounding trim before ordering
- Make sure the substrate is clean, dry, stable and free from dust or loose coatings
- Dry-fit the P5040D element and mark its position before applying adhesive
- Use a polyurethane (PU) mounting adhesive selected for the substrate and project conditions; silicone adhesive must not be used
- Mechanical fixing with suitable screws and anchors is mandatory, particularly where the element is exposed to movement, impact or outdoor conditions
- Keep the piece aligned while the adhesive system is installed according to its technical instructions
- Fill joints and screw points with compatible filler, then sand with 180-220 grit abrasive paper
- Apply additional primer only when required or preferred by the chosen paint system, followed by two compatible paint coats
- For exterior applications, use UV-resistant paint and seal joints with exterior-grade filler
- Clean P5040D with a soft, slightly damp cloth and avoid abrasive cleaners, hard brushes and solvents that may damage the coating or molded surface
- Inspect painted areas, joints and fixing points periodically, especially on exterior elevations
- If cracking or separation appears, repair the affected area before repainting
- Recoating intervals depend on the selected paint system, exposure and cleaning frequency
- When repainting, prepare the surface carefully and follow the coating manufacturer's primer and application instructions
- The factory primer prepares the surface, but any additional primer remains optional and should be chosen in consultation with the paint supplier
Can P5040D be used on an exterior facade?
Yes. P5040D is suitable for interior and exterior decorative applications when the substrate, fixing method and coating system are appropriate. On an exposed facade, apply a UV-resistant exterior paint and protect joints and screw points with compatible exterior filler. The element is decorative and must not be used to carry structural loads. Project conditions, substrate movement and the selected paint manufacturer's instructions should be reviewed before installation.
How is the pilaster element installed and painted?
Install P5040D on a clean, dry and sound surface using polyurethane (PU) mounting adhesive together with mandatory mechanical fixing. Do not use silicone adhesive. After the element is aligned, fill joints and fixing points, then sand with 180-220 grit abrasive paper. Apply primer if required by the selected paint system and finish with two compatible coats. Exterior projects require UV-resistant paint.
How durable is P5040D and what is its density?
P5040D is made from rigid, closed-cell polyurethane with a density of 150-220 kg/m³. Its technical profile specifies water absorption below 1%, high dimensional stability and dimensional stability tested between -20 °C and +70 °C. The surface is hard, paintable and repairable. Actual service life depends on substrate preparation, mechanical fixing, paint compatibility, exposure and ongoing maintenance.
What advantages does polyurethane have over plaster or timber?
Compared with plaster, P5040D is lighter and less vulnerable to breakage during handling and installation. Compared with timber, the closed-cell material resists moisture-related decay and insect damage. It also preserves molded architectural detail while remaining easy to fill, sand and repaint. The element is not structural, so it should be installed as a decorative finish over a suitable wall or column.
Can the P5040D surface be painted in a custom colour?
Yes. P5040D is supplied with a factory-primed surface intended to support water-based or synthetic paint systems. The final colour depends on the selected coating. Additional primer application is optional, but paint manufacturers may require their own primer for warranty coverage. Polure does not guarantee the performance of a paint system selected independently, so compatibility should be confirmed with the coating supplier.